What size heat pump does your house need?
This works out how much heat your home loses, the heat pump output that implies, and whether it would cost more or less to run than what you have now.
It shows you every step of the arithmetic, where each number came from, and when it was last checked. It is an estimate built from a dozen answers, not a survey — the limits are set out in full with your result.
! This nation is not ready yet
We would rather show you nothing than a confident number built on the wrong data.
2 Heat loss and size
kW
design heat loss at , pointing to a heat pump rated
The working
| Element | Area, m² | U‑value | Loss, W/K |
|---|---|---|---|
| Heat lost per degree of temperature difference | W/K | ||
| Multiplied by the design temperature difference | kW | ||
3 Would it be cheaper to run?
efficiency your house needs,
just to break even
median measured across
428 real UK installations
Yearly running cost
Most calculators assume the efficiency printed on the manufacturer's label. Field monitoring found real installations came in below that label figure in of homes, so this page uses the measured spread instead. It produces smaller savings than you will see elsewhere.
4 What it would cost
5 Your quote
6 What this cannot tell you
- This is a whole-house estimate. A real design needs a room-by-room calculation to BS EN 12831‑1:2017, which is what MCS requires before anyone installs anything.
- It cannot size your radiators, check whether your pipework is wide enough, or tell you if the outdoor unit will pass planning and noise rules.
- It assumes a plain rectangular house. Extensions, conservatories, odd shapes and large amounts of glazing all move the answer.
- Nobody can give you a fixed price without visiting. Treat this as a way of checking whether a quote is sensible, not as a quote.
The sensible next step is to have an MCS-certified installer do the full calculation on your property, and to get more than one quote.
7 Method and sources
How the heat loss is worked out
- Areas are derived from your floor area, number of floors and house type, assuming a rectangular plan one and a half times as long as it is wide. Walls shared with a neighbour are excluded.
- Each element's area is multiplied by its U‑value — how many watts pass through a square metre for each degree of temperature difference.
- Air leaking in and out is added: 0.33 watt-hours per cubic metre per degree, multiplied by the air changes per hour and the volume of the house.
- The total is multiplied by the difference between 21°C indoors and the coldest design temperature for your region. That gives the design heat loss in kilowatts.
- Yearly heat is the same total multiplied by regional heating degree days. Hot water is added separately from the number of people.
Every number this page uses
| What | Value | Source |
|---|
Known gaps
These are not yet traced to a published source, and are flagged here rather than hidden: