What size heat pump does your house need?

This works out how much heat your home loses, the heat pump output that implies, and whether it would cost more or less to run than what you have now.

It shows you every step of the arithmetic, where each number came from, and when it was last checked. It is an estimate built from a dozen answers, not a survey — the limits are set out in full with your result.

1 Your house

Insulation data, age bands and grants all differ by nation.

Only the first part is used, to look up how long your heating season is.

These are the weather stations MCS designs against. Pick whichever is closest to you.

m² Every floor added together. A rough measurement is fine.

Shared walls lose no heat, so this matters more than it sounds.

Sets the assumed insulation standard where you do not know it.

If you are not sure, leave the default for your build year.

Depth between the joists. A joist is about 100 mm deep, for scale.

Only affects hot water, not the size of the heat pump.

Condensing boilers have a plastic flue and a condensate pipe draining away. Oil and LPG are not here yet — those prices are not capped, so we have no dated source to quote.

£ If your boiler is near the end anyway, this is the fairer comparison. We do not guess a figure.

£ We will show you where it sits against what grant-funded installs actually cost.

No email address, no sign-up. Nothing you type is sent anywhere.

7 Method and sources

How the heat loss is worked out

  1. Areas are derived from your floor area, number of floors and house type, assuming a rectangular plan one and a half times as long as it is wide. Walls shared with a neighbour are excluded.
  2. Each element's area is multiplied by its U‑value — how many watts pass through a square metre for each degree of temperature difference.
  3. Air leaking in and out is added: 0.33 watt-hours per cubic metre per degree, multiplied by the air changes per hour and the volume of the house.
  4. The total is multiplied by the difference between 21°C indoors and the coldest design temperature for your region. That gives the design heat loss in kilowatts.
  5. Yearly heat is the same total multiplied by regional heating degree days. Hot water is added separately from the number of people.

Every number this page uses

WhatValueSource

Known gaps

These are not yet traced to a published source, and are flagged here rather than hidden: